Description Application Customer Substation; Single License; Online activation
The Customer Substation Application allows customer systems to communicate with the regional grid operator (control technology) in compliance with the IEC 60870-5-101 or IEC 60870-5-104 guidelines.
Measured values like voltage, reactive power, active power and station parameters (position messages) are determined and monitored.
The application enables automatic mapping of the respective data points according to the technical connection requirements (TCRs) of the grid operators.
The station can be customized depending on the number of sections.
The application connects all relevant measurement and protection systems. For standard devices, communication templates are stored for easy configuration.
Optionally, data can also be transmitted to a cloud (MQTT).
A direct marketer interface is available.
Available Options:
As an option, a certified power plant control (Item No. 2759-203/211-1000) can be activated and linked to various actuators.
The WagoAppRTU_Slaves library on which the application is based provides simple function blocks for use with specific power system operators.
They enable customer systems to communicate with the grid operator per IEC 60870-5-101 or IEC 60870-5-104.
Supported grid operators: E.ON (Avacon Netz, Bayernwerk Netz, Schleswig Holstein Netz, E.DIS Netz); EWE NETZ; Netze BW; Westnetz, VSE; WEMAG; Mitnetz and SachsenNetze. Note: Additional information available upon request
Complete Solutions:
8007-100/1000-247 Control Cabinet Customer Substation – standard
Design according to the TCR of the grid territories of E.ON and grid subsidiaries (AVACON, E.DIS, SH Netz, Bayernwerk), Westnetz, Wemag Netz, NetzeBW, EWE
8007-100/1000-270 Control Cabinet Customer Substation – combination, incl. protection
Design according to the TCR of the grid territories of E.ON and grid subsidiaries (AVACON, E.DIS, SH Netz, Bayernwerk), Westnetz, Wemag Netz, NetzeBW, EWE
Including protective devices: - SEG MRA4; - NA protection Ziehl UFR1001E
Note: Other protective devices upon request!
Functions:
Control sections
- Input panel (1-n)
- Transfer panel/network connection point
- Metering panel
- Disconnectors, HH fuses
- Generation plants (various energy types)
- Additional generation units
Compatible Controllers:
750-8210; PFC200; G2; 4ETH
750-8210/025-000; PFC200; G2; 4ETH; T
750-8210/040-000; PFC200; G2; 4ETH; XTR
750-8211; PFC200; G2; 2ETH 2SFP
750-8211/040-000; PFC200; G2; 2ETH 2SFP; XTR
750-8212; PFC200; G2; 2ETH RS
750-8212/025-001; PFC200; G2; 2ETH RS; TELE; T
750-8212/025-002; PFC200; G2; 2ETH RS; TELE; T; ECO
750-8212/040-000; PFC200; G2; 2ETH RS; XTR
750-8212/040-001; PFC200; G2; 2ETH RS; Tele; XTR
750-8212/040-010; PFC200; G2; 2ETH M12; RS; XTR
750-8217; PFC200; G2; 2ETH RS; 4G
750-8217/025-000; PFC200; G2; 2ETH RS; 4G; T
Main attributes Application Customer Substation; Single License; Online activation
Reviews about Application Customer Substation; Single License; Online activation
There are no reviews for this product.
Questions and Answers (FAQ) Application Customer Substation; Single License; Online activation